DV Power

DV-Power-RMO-TT PENGUJIAN TEMPERATURE RISE TRANSFORMATOR 3 PHASA-Heat Run Test

ABSTRAK Panas merupakan salah satu penyebab menurunnya ketahanan isolasi trans-formator, padahal tipe isolasi transformator mempunyai tingkat ketahanan terhadap suhu yang berbeda-beda. Tujuan pengujian kenaikan suhu adalah untuk mengetahui kenaikan suhu minyak dan belitan transformator. Pengujian menggunakan metode “HEAT RUN.” Salah satu fitur yang disediakan oleh Software DV-Win adalah mode uji Heat Run otomatis. Instrumen melakukan pengukuran resistensi berliku / winding resistance. Instrumen perlu dihubungkan ke Trafo Winding secepat mungkin setelah transformator dimatikan/ Off-Line. Metode ini memastikan bahwa hasil interpolasi yang paling akurat akan diperoleh. Saluran pengukuran resistensi 1 (VS_1) digunakan…

Read More
DV Power

DV-Power – Handheld Circuit Breaker Analyzer & Timer CAT-H

Handheld Circuit Breaker Analyzer & Timer CATH is a digital instrument for circuit breakers condition assessment. CAT-H records graphs of both, open and close coil currents, timing of main arcing contacts, DC substation battery voltage.The timing channels record closing and opening of the main contacts and can also measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).CAT-H provides an easy selection of different operating modes: Open (O) Close (C) Trip free (CO) Reclose (O-C) Close-Open (C-O) Open-Close-Open (O-C-O)Multiple operations, such as Open-Close and Open-Close-Open, can…

Read More
DV Power

Circuit Breaker Analyzer & Timer Handheld CAT-H

 Compact and ergonomic design – only 1,6 kg (3.5 lbs) Simple and easy to operate Battery operation for up to 8 hours Timing and coil current measurement Coil control (built-in) for OPEN and CLOSE coil Graphical results for quick interpretation Touch screen color display 145 mm (5.7 in) On-site analysis of test results(overlay up to 4 records in graphical form) ApplicationThe list of the instrument applications includes: Timing measurement of up to 3 main contacts (1 break per phase) including pre-insertion resistors (if present in the circuit breaker) and…

Read More
DV Power

True Three-Phase Transformer Turns Ratio Tester TRT400

 Single-phase test voltages up to 430 V AC True three-phase test voltages up to 3×250√3V AC Turns ratio range 0,8 – 50 000 The best turns ratio accuracy of 0,03% Large 7” graphical touch screen display Automatic vector group detection Built-in tap changer control unit Interchangeable test leads with Three-phase Winding Ohmmeters & Tap ChangerAnalyzers TWA ApplicationThe list of instrument application includes: Turns ratio measurement Turns ratio deviation calculation Excitation current measurement Phase angle measurement Automatic vector group detection Verification of demagnetization process Magnetic balance test Distributor DV-Power TRT400…

Read More
×